- Overview
- Specifications
- Downloads
- Video
Rebel Provides Quick Payback with World Class Energy
Savings and Unbeatable Part-Load Efficiencies!
Rebel’s innovative design creates air conditioning part-load energy efficiencies (as high as 20.6 IEER) that overwhelmingly surpass ASHRAE’s 90.1 performance standard by a staggering 84%. Rebel also offers great energy savings in the heating mode with COP’s at 47°F that are as high as 3.8. And during winter months, Rebel’s heat pump provides significantly lower operating costs than any type of alternative mechanical heat, including traditional gas furnaces. |
|
The Department of Energy Announces Rebel as the First Unit to Exceed its High-Efficiency Commercial Rooftop Air Conditioner Challenge
The Daikin McQuay Rebel system is the first rooftop unit to exceed the DOE’s voluntary challenge which seeks manufacturers to develop a new generation of high-efficiency, cost-effective air conditioners for commercial buildings that meet or exceed a partload efficiency standard of 18 IEER. The challenge aims to reduce energy use by as much as 50 to 60 percent over current equipment and is part of the DOE’s broad efforts to partner with industries in support of innovative building technologies that will reduce energy use, save money, and increase American competitiveness.
The Daikin McQuay Rebel system proudly leads that challenge with IEERs of up to 20.6. Rebel is indisputably the most energy efficient packaged rooftop system on the market and can be configured as a 100% dedicated outdoor air system, variable air volume (VAV), Single-Zone VAV, or constant air volume (CAV) system that provides better comfort control, unmatched energy savings, and superior part-load efficiencies in low rise building applications
Click here for more information on the DOE challenge.
Physical Data - DPS 003 through 015
| Model | Small Cabinet | Large Cabinet | ||||||
| 003 | 004 | 005 | 006 | 007 | 010 | 012 | 015 | |
| Cooling only performance | ||||||||
| Gross cooling capacity (tons) | 3 | 4 | 5 | 6 | 7.5 | 10 | 12 | 15 |
| Nominal airflow (cfm) | 1125 | 1500 | 1875 | 2400 | 2650 | 3500 | 4200 | 5250 |
| EER | 13.5 | 12.4 | 13.0 | 11.6 | 12.6 | 12.5 | 12.1 | 11.0 |
| IEER | 16.9 | 17.0 | 18.5 | 19.8 | 20.6 | 19.4 | 18.5 | 18.0 |
| Heat pump performance | ||||||||
| High temperature capacity @ 47°F (MBh) | 34 | 43 | 54 | 64 | 78 | 110 | 134 | NA |
| COP @ 47°F | 9.2 | 8.9 | 8.5 | 3.69 | 3.66 | 3.42 | 3.33 | NA |
| Low temperature capacity @ 17°F (MBh) | 20 | 24 | 33 | 39 | 47 | 64 | 77 | NA |
| COP @ 17°F | N/A | N/A | N/A | 2.75 | 2.90 | 2.67 | 2.50 | NA |
| Electric heat performance | ||||||||
| Control options | 2/4/SCR | 4/SCR | ||||||
| kW (low/medium/high heat) | 6/12/18/30 | 18/36/54/72 | ||||||
| Gas heating performance | ||||||||
| Input capacity (MBh) | 80/120/160 | 200/300/400 | ||||||
| Number of stages (staged option) | 2 | |||||||
| Turndown (modulating options) | 5:1 | 5:1, 10:1 | ||||||
| Gas connection size (mpt) | 1/2" | 3/4" | ||||||
| Steady state efficiency | 80% | |||||||
| Heating coil | ||||||||
| Type | Hot Water | |||||||
| Rows / FPI (high heat/low heat) | (2/10) / (1/8) | |||||||
| Face area (sq ft) | 2.5 | 5.4 | ||||||
| Compressors | ||||||||
| Quantity / Type | (1) Inverter Scroll | (1) Inverter Scroll, (1) Fixed Speed Scroll | ||||||
| Number of stages | Modulating | |||||||
| Refrigerant | R-410A | |||||||
| Indoor coil | ||||||||
| Rows / FPI | 3/16 | 4/16 | 4/14 | 4/14 | 3/15 | 4/15 | 4/15 | 4/15 |
| Face area (sq ft) | 6.0 | 14 | 15.4 | 15.4 | 15.4 | |||
| Capacity control | Electronic Expansion Valve (EEV) | |||||||
| Outdoor coil | ||||||||
| Type | Copper tube | |||||||
| Rows / FPI | 2/16 | 2/16 | 3/16 | 3/16 | 3/16 | 4/16 | 4/16 | NA |
| Indoor fan | ||||||||
| Type | Centrifugal Airfoil (SWSI) | |||||||
| Quantity / Diameter2 | (1) 12", (1) 14", (1) 16" | (1) 14", (1) 16", (1) 22" | (1) 22" | |||||
| Quantity / Diameter3 | (1) 12", (1) 14", (1) 16" | (1) 14", (1) 16", (1) 22" | ||||||
| Drive type | Direct Drive | |||||||
| Motor HP range | 1.3 / 2.3 / 4.0 / 8.0 | |||||||
| Hot gas reheat coil | ||||||||
| Coil type | Microchannel | |||||||
| Control type | Modulating | |||||||
| Temperature rise | 20° | |||||||
| Filters | ||||||||
| Type | 2" and 4" Slideout Racks | |||||||
| Area (sq ft) | 7.1 | 16 | ||||||
| Qty. - size | 4 – 16 × 16 | 6 – 18 × 24 | ||||||
NOTE: | ||||||||
| Model | |||||||||
| Small Cabinet | Large Cabinet | ||||||||
| 003 | 004 | 005 | 006 | 007 | 010 | 012 | 015 | ||
| Weight (lbs.) | |||||||||
| Base weight* | 1000 | 1000 | 1025 | 1058 | 1600 | 1600 | 1600 | 1600 | |
| Heat Pump | 1030 | 1030 | 1058 | 1058 | 1660 | 1660 | 1660 | 1660 | |
| Electric heat | 45 | 45 | 45 | 45 | 100 | 100 | 100 | 100 | |
| Hot water 2 row | 11 | 11 | 11 | 16.5 | 30 | 30 | 30 | 30 | |
| Hot water 1 row | 32 | 32 | 32 | 20 | 31 | 31 | 31 | 31 | |
| Gas heat | 75 | 75 | 63 | 93 | 186 | 186 | 186 | 186 | |
| Hot gas reheat | 8 | 8 | 12 | 12 | 28 | 31 | 31 | 31 | |
| Economizer | 163 | 163 | 163 | 163 | 308 | 308 | 308 | 308 | |
| High capacity coil | 105 | 105 | 105 | 105 | 215 | 215 | 215 | 215 | |
| * Includes standard cooling coil | |||||||||
| Fan weights | |||||||||
| 12 Inch (310 mm) | 87 | ||||||||
| 14 Inch (360 mm) | 91 | ||||||||
| 16 Inch (360 mm) | 115 | ||||||||
| 22 Inch (560 mm) | 115 | ||||||||
| Curb weight | |||||||||
| 14" | 156 | 200 | |||||||
| 24" | 230 | 295 | |||||||
Control
Application Software for Rebel™ Rooftop with MicroTech® III Controller - (1,451K) (Pub: 2012/06/07)
Models:DPSMicroTech III Unit Controller Application Software for Rebel Rooftop Units. Warning! The wrong application can cause equipment damage and severe personal injury. Application codes must be used only by trained technicians experienced with the particular equipment.
Unit
A/SP 31-161 Rooftop Energy Recovery Systems - (1,432KB) (Pub: 2012/11/06)
Models:DPS,MPS,OAH,RAH,RDE,RDT,RFS,RPSApplied Rooftop Systems and Air HandlersUnit
A/SP 31-341 Introductory Rebel Commercial Packaged Rooftop Brochure - (1,358KB) (Pub: 2012/06/29)
Models:DPS2 page introductory flyer for Rebel 3-12 ton units (model DPSUnit
A/SP 31-344 Rebel Commercial Packaged Rooftop Systems Brochure - (1,221KB) (Pub: 2012/06/29)
Models:DPS6 page brochure for Rebel 3-12 ton units (model DPS)Unit
A/SP 31-347 Rebel Heat Pump Applications - (842KB) (Pub: 2012/07/06)
Models:DPSNOT FOR PURCHASE/PRINT ONLY - 6 page flyer covering Rebel heat pump advantagesUnit
A/SP 31-349 Rebel Energy Efficiency - Inverter Scroll vs. Digital Scroll Compressor Technology - (1,326KB) (Pub: 2012/09/18)
Models:DPS2 page flyer on the Rebel energy efficient inverter scroll vs. competitor digital scroll compressor technology.Unit
A/SP31-293 100 Percent Dedicated Outdoor Air Systems - (743KB) (Pub: 2012/09/17)
Models:DPS,MPS,RPSRooftop 100 Percent OA sytems brochureControl
A/SP 31-260 Open Choices for MicroTech III Applied Air Handling Systems - (1,724KB) (Pub: 2012/05/22)
Models:DPS,MPS,RPS,SWP,SWTOpen Choices feature for MicroTech III applied air handling systems including RoofPak applied rooftop, Maverick II commercial rooftop, Rebel packaged rooftop and the commercial Self Contained unit.Control
A/SP 31-300 MicroTech System Manager Spec Sheet - (228KB) (Pub: 2012/12/18)
Models:DPS,MPS,RPS,SWP,SWTSubmittal specification sheet for the System Manager of the MicroTech Integrated System for either VAV or WSHP applications. Electronic format.Control
A/SP 31-346 MicroTech Integrated System for Water Source Heat Pump Applications - (2,298KB) (Pub: 2012/09/26)
Models:DPS,MPS,RPS,WGSH,WGSV,WGTH,WGTVSales brochure describing the components and the advantages of the Daikin McQuay MicroTech Integrated System for water source heat pump applicationsControl
DOAS-VRV System Brochure, ASP 31-335 - (1,757KB) (Pub: 2012/06/29)
Models:DPS,MPS,RPS,SWP,SWTBrochure on combining Daikin McQuay dedicated 100% outdoor air system equipment with Daikin variable refrigerant volume (VRV) equipment
Unit
CAT 256-6 Rebel Commercial Packaged Rooftop Systems - (4,362KB) (Pub: 2013/03/20)
Models:DPSHeating and Cooling units, Models DPS 003-015, 3 to 15 tons, R410A Refrigerant, MicroTech III Unit Controller and Energy Recovery Wheel.
Control
ED 15112-11 Protocol Information for MicroTech® III Rooftop and Self Contained Unit Controllers - (1,103KB) (Pub: 2012/07/13)
Models:DPS,MPS,RAH,RDE,RDS,RDT,RFS,RPE,SWP,SWTBACnet® and LonWorks® protocol information for Rooftop and Self Contained units with MicroTech III unit controllersControl
ED 15113-4 BACnet PICS for MicroTech III Applied Air Handlers - (164KB) (Pub: 2012/04/24)
Models:DPS,MPS,RAH,RCS,RDS,RDT,RFS,RPE,RPS,SWP,SWTBACnet protocol implementation conformance statement (PICS) for Applied Air Handling Units with MicroTech III unit controllers
Unit
IM 1125-4 Rebel Commercial Packaged Rooftop Systems - (5,833KB) (Pub: 2013/03/20)
Models:DPSModels DPS 003-05, 3 through 15 tons with R-410A refrigerant, MicroTech III Unit Controller and Energy Recovery WheelUnit
OM 1164 Rebel Commercial Packaged Rooftop Systems Quick Start Guide - (479KB) (Pub: 2012/08/31)
Models:DPS11x17 condensed start-up document for Rebel. Read manuals listed in document before operating. Select 11x17 paper when printing.Control
IM 1005-2 MicroTech® III Remote User Interface - (538KB) (Pub: 2012/04/23)
Models:AGZ,AWS,DPS,MPS,RAH,RDE,RDS,RDT,RFS,RPE,SWP,SWTInstallation and maintenance manual for the MicroTech III remote user interface. Used with RoofPak, Maverick II and Rebel rooftop units; Self Contained Units; Pathfinder Chillers and Air Cooled Scroll Model AGSD Chillers.Control
IM 916-3 MicroTech III Rooftop and Self Contained BACnet IP Comm Module - (346KB) (Pub: 2012/04/24)
Models:DPS,MPS,RAH,RCS,RDE,RDS,RDT,RFS,RPE,RPSInstallation manual for the BACnet IP communication module used with the MicroTech III Rooftop and Self Contained Unit Controller. Applied to Applied Rooftop and Maverick II commercial Rooftop units, as well as to Self Contained units.Control
IM 917-2 BACnet MS-TP Communication Module for MicroTech III Rooftop and Self Contained - (443KB) (Pub: 2012/04/24)
Models:DPS,MPS,RAH,RCS,RDE,RDS,RDT,RFS,RPE,RPSInstallation manual for the BACnet MS-TP communication module for Rooftop and Self Contained units with the MicroTech III Unit ControllerControl
IM 918-2 LonWorks Communication Module for MicroTech III Rooftop and Self Contained - (365KB) (Pub: 2012/04/24)
Models:DPS,MPS,RAH,RCS,RDE,RDS,RDT,RPE,RPS,SWP,SWTInstallation manual for the LonWorks Communication Module for the the Rooftop and Self Contained units with the MicroTech III unit controller. This comm module can be used on Applied and Commercial rooftop units as well as Self Contained units.Control
IM 919-2 MicroTech III for Air Handling Units - (5,014KB) (Pub: 2013/04/09)
Models:DPS,MPS,RAH,RCS,RDS,RDT,RFS,SWP,SWTMicroTech III Unit Controller for Commercial Rootop, Applied Rooftop and Self-Contained SystemsControl
OM 1141-2 MicroTech III for Rebel Commercial Packaged Rooftop Systems - (2,605KB) (Pub: 2013/02/22)
Models:DPSMicroTech III Unit Controller for Rebel Commercial Packaged Rooftop SystemsControl
OM 1190 Daikin McQuay MD4 VFD - (3,861KB) (Pub: 2013/01/30)
Models:CAC,CAH,DPS,LAH,MPS,OAC,OAH,RAH,RDE,RDS,RDT,RFR,RPE,RPS,SWP,SWTMD4 Variable Frequency Drive Controller for Packaged Rooftop Units: DPS, MPS, RPS, RFS, RDT, RPE, RDE; Rooftop Air Handler Units: RDS, RAH; Indoor Air Handler Units: LAH, CAH; Outdoor Air Handler Units: OAH; Vertical Self-Contained Units: SWP, SWTControl
OM 1191 Daikin McQuay MD5 VFD - (3,042KB) (Pub: 2013/02/13)
Models:CAC,CAH,DPS,LAH,MPS,OAC,OAH,RAH,RDE,RDS,RDT,RFR,RPE,RPS,SWP,SWTMD5 Variable Frequency Drive Controller for Packaged Rooftop Units: DPS, MPS, RPS, RFS, RDT, RPE, RDE; Rooftop Air Handler Units: RDS, RAH; Indoor Air Handler Units: LAH, CAH; Outdoor Air Handler Units: OAH; Vertical Self-Contained Units: SWP, SWTControl
OM 920-4 MicroTech III for Commercial Rootop, Applied Rooftop & Self-Contained Systems - (1,696KB) (Pub: 2013/04/29)
Models:DPS,MPS,RAH,RCS,RDS,RDT,RFS,SWP,SWTMicroTech III Unit Controller for Commercial Rootop, Applied Rooftop and Self-Contained SystemsAccessory
IM 1199 DPS/MPS/RAH/RPS/SWP Space Sensor - (916KB) (Pub: 2013/05/09)
Models:DPS,MPS,RAH,RPS,SWPSpace temperature sensor designed to work with the MicroTech® III unit controller
Unit
Replacement Parts List: 7000236 - (1,456KB) (Pub: 2013/02/22)
Models:DPSRPL: DPS 007- 012, Vintage A, Rebel Commercial Packaged RooftopUnit
Replacement Parts List: 7000242 - (1,186KB) (Pub: 2013/05/03)
Models:DPSRPL: DPS 005- 006, Vintage A, Rebel Commercial Packaged RooftopUnit
Replacement Parts List: 7000243 - (1,194KB) (Pub: 2013/05/03)
Models:DPSRPL: DPS 003- 004, Vintage A, Rebel Commercial Packaged Rooftop
Unit
Rebel (Revit 2010 Zip) - (29.5MB) (Pub: 2013/04/17)
Models:DPSRevit 2010 content for commercial packaged rooftop model DPS, Rebel R-410A units with Energy Wheel. Rebel units are 3-15 ton.
| Rebel Provides Quick Payback with World Class Energy Savings and Unbeatable Part-Load Efficiencies! Updated to include Energy Recovery Wheels! |
|
| Chris Pedecine, Solutions Plaza Manager shows you how quiet the Rebel Rooftop really is! |
|